REL-AC215IP : ROSSLARE Advanced Scalable Networked Access Controller

Login to see prices
SKU: REL-AC215IP Categories: , ,

Description

SpecificationsDownload
Electrical Characteristics
ACU Power Supply Voltage 12 VDC ,regulated from built-in PS-14 regulated power supply/ charger module
ACU Power Supply Max Current Panel output: 0.5 A input current limitation (PS-14)
Lock output: 1.5 A
Relays 4 fully programmable 5 A, N.O. and N.C. relay outputs
Battery Charger 12 V sealed lead acid (SLA) up to 7 Ah (PS-14)
Maximum Current for Readers 370 mA at 12 VDC
Operational Characteristics
Capacity 30000 users
History Event Log Size 20000 events
Inputs 4 supervised, dual-resistor, 2 state end-of-line inputs, hi-impedance, active low 5 VDC
Readers Two reader ports, standards and non-standards protocols
Connectivity RS-485/232, Dial-up (using MD-N33),onboard TCP/IP
Networking 32 units/subnet, 1023 subnets (Max 2046 doors) using AxTraxNG™ software
Audio/Visual Built-in sounder (Alarm, Chime, Bell)
11 on-board and 3 P.S. LEDs
Time Zones and Groups 128 multiple segment time zones, 64 holidays, 30000 access groups
Special Features Interlock, first person delay, auto relock, scheduled outputs operation, 4 programmable site codes, Extended unlocked time, parking lot management, fully interconnectedness
Physical Characteristics
ACU Board Dimensions 168 x 121mm x(6.61 x 4.76 in.)
Enclosure Metal, locked 326 x 263 x 97 mm (12.8 x 10.4 x 3.82 in.)
Weight 3.8 kg (8.4 lbs)
Environmental Characteristics
Operating Environment Indoor installation only
Operating Temperature 0°C to 49°C (32°F to 120°F)
Operating Humidity 0 to 85% (non-condensing)
RFI Protection >20 V/m up to 1000 MHz
Date Title Type Download
2018-02-23 REL-AC215IP Product Catalogue PDF
preloader